Abstract
This paper compares the electromagnet torque characteristics of ALA+PM rotor synchronous motor with the conventional permanent magnet motor, the former holds on linearity relationship with the increase of the stator flux linkage, but the later needs restrict condition. The direct electromagnet torque control is the best control method for ALA+PM rotor synchronous motor, but the stator current can increase if the stator flux linkage is bigger or smaller than magnet flux linkage, the maximum torque current percent ampere control method is used to overcome the disadvantage.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.