Abstract

To The article provides information on the results of studying the parameters of acoustic emission signals during the destruction of the liner material and micro-plastic of the power shell of a metal-composite high-pressure cylinder. B-200 within the framework of a complex of studies to create an acoustic-emission portrait of metal-composite high-pressure cylinders. It was found that the most informative parameter when carrying out technical diagnostics of a liner is the signal amplitude recorded in the private range of 60-80 kHz, and a sign of microplastic rupture is the emission of acoustic emission signals reaching 82 dB.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.