Abstract

Indirect test method of installing vibrating wire strain gauges as sensors in outer surface of steel tube rib is adopted to carry out the research of concrete-filled steel tube (CFST) self pre-stress test for a half-through CFST arch bridge with a main span of 240m. The results show that indirect test method is a practical approach for self pre-stress test, and the measured value of self pre-stress from this method is much smaller than that of being theoretically calculated by concrete free expansion ratio.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.