Abstract

The paper adopted Coagulation-Fenton Oxidation Method on treating the wastewater of 6-nitro-1,2 diazonium oxygroup naphthalene-4-sulfoacid production process (i.e. 6-nitry wastewater), introduced the treatment effect of the combined technology used on 6-nitry wastewater, and studied the factors influencing the treatment effect, to determine the reasonable parameters of the technology on treating 6-nitry wastewater. The results showed that Using polyaluminium chloride (mass fraction 2%) as flocculant for treating 6-nitry wastewater, the COD removal rate reached up to 48.7%; Making Fenton reagent oxidation treatment on coagulation yielding water, under the best conditions for solution acidity controlled at pH3 or so, in the 100 mL wastewater, 30% hydrogen peroxide was 5.0 mL, 0.5 mol/L ferrous sulfate solution was 4.0 mL, reaction time was 60 min, the COD removal rate could reach 98% or more.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.