Abstract

To investigate the reproducibility of measurements of hepatic triglyceride content (HTGC) in subjects with normal HTGC using localized (1)H-magnetic resonance spectroscopy ((1)H-MRS) and a clinical 1.5T scanner. The (1)H-MRS acquisition was performed with a common protocol using the whole-body coil and no respiratory triggering. An upper limit of normal HTGC of 5.56% was used. Duplicate measurements, including subject repositioning, were acquired from 23 subjects, 19 of whom had a normal HTGC. The mean coefficient of variation (CV) from the duplicate measurements was 14.8% (20.5% before exclusion of a subject who was considered to be an outlier). Mean CVs of subgroups below and above the 1% HTGC limit were 19.8 and 7.0 respectively. The mean CV calculated in subjects with HTGC in the normal range was found to be higher than CVs of wide range HTGC groups reported in the literature. It is concluded that the reproducibility of HTGC measurements using (1)H-MRS depends on the HTGC range. These findings are of importance in reproducibility studies and in estimations of required study group sizes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.