Abstract

To test the repeatability of a reference region (RR) model for the analysis of dynamic contrast-enhanced MRI (DCE-MRI) in a mouse model of cancer at high field. Seven mice were injected with 10(6) 4T1 mammary carcinoma cells and imaged eight to 10 days later on a Varian 7.0T scanner. Two DCE-MRI studies were performed for each mouse (separated by 2.5 hours). The RR model was used to analyze the data, and returned estimates on the perfusion-permeability index (Ktrans) for the RR and the tissue of interest (TOI), as well as the extravascular extracellular volume fraction (ve) for the TOI. When the first injection was compared with the second injection, all parameters tested were highly correlated (r2=0.90, 0.62, 0.82 for the RR Ktrans, TOI Ktrans, and TOI ve, respectively, with P<0.001 for all). To observe a statistically significant change (at the 5% level) in a treatment study with seven animals in each group, log10 changes of 0.084 and 0.077 in the tumor Ktrans and ve, respectively, are required. If a reliable arterial input function (AIF) is unavailable, the RR model is a reasonable alternative to measuring MRI contrast-agent (CA) kinetics in mouse models of cancer at high field.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.