Abstract
To investigate the repeatability in vessel caliber measurements by optical coherence tomography angiography (OCTA). In this prospective study, 28 patients (47 eyes) underwent sequential OCTA imaging of the optic nerve head and macula. Two independent masked graders measured vessel caliber for sequential images of the optic nerve head and macula. The average vessel width was determined and variability between graders and images. A total of 8400 measurements of 420 vessels from 84 OCTA images were included in the analysis. Overall, inter-grader agreement was excellent (ICC 0.90). The coefficient of variation (CoV) for all repeated OCTA images was 0.10. Greater glaucoma severity, older age, macular location, and diagnosis of diabetes were associated with thinner vessels (p < 0.05). CoV was higher in the peripapillary region (0.07) as compared to the macula (0.15). ICC was high for all subgroups except for the macula (ICC = 0.72). Overall, the repeatability of vessel caliber measurements by OCTA was high and variability low. There was greater variability in the measurement of macular vessels, possibly due to technical limitations in acquiring accurate vessel widths for smaller macular vessels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.