Abstract

This chapter will follow the concept of the continuum of repair necessary for increasingly larger eyelid defects as discussed in Chap. 35. After the lesion is excised, if the gap is greater than approximately 3 mm when the two edges of the lid are grasped with forceps or skin hooks and pulled together, a repair technique that permits closure of this larger defect must be used. The Tenzel rotational flap, or semicircular flap, proves to be an ideal technique. The semicircular flap can be used for either upper or lower lid reconstruction. It is useful for defects affecting up to 40–50% of the medial or central portion of the eyelid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.