Abstract

Net outward wave motion of secretions from airways by two-phase gas-liquid transport is favored by higher airflow during expiration than inspiration. This can be accomplished by IRV in which the controlled mode of mechanical ventilation is adjusted such that the inspiratory cycle is prolonged and the expiratory phase is shortened. Studies were done on six anesthetized, nasally intubated sheep. Simulated mucus was instilled into the bronchi at 15-min intervals during I-E ratio of 1:2.7, 1.9:1, and 3:1. The IRV modes of 1.9:1 and 3:1 promoted transport of simulated mucus outward. Neither systemic blood pressure nor cardiac output were altered by IRV. Thus, IRV might be useful in the management of excessive bronchial secretions in mechanically ventilated patients. However, clinical trials of IRV should take into account its potential for producing adverse hemodynamic effects and barotrauma in patients with compromised cardiac function due to auto-PEEP attendant with its usage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.