Abstract

During fire incidents, optical fibers located with-in a fire-resistant cable are usually exposed to temperatures of 800ºC to 1000ºC. Hot fibers generate narrowband thermal (incandescent) radiation and collect broadband thermal radiation originating from the heated surroundings. The power of the second component, initially negligible, increases with time due to the rising number of fiber cracks and other defects acting as couplers for external radiation. Thermal radiation may interfere with fiber attenuation measurements performed during a fire test, but is rather unlikely to prevent data transmission with typical GbE and 10 GbE transceivers during a fire. This problem may be remedied by combining the following methods: using single mode fibers instead of multimode fibers, using bandpass filters to block thermal radiation, and selecting proper transmitter power, wavelength and photodetector.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.