Abstract

This paper presents the design and reliability tests of a novel micro-electro mechanical varactor based on a double actuation mechanism allowing for overall capacitive ratio Cr of 5.2 and continuous capacitive ratio Cr⁎ of 2.6. The device has been modeled in ANSYS® multiphysics environment and manufactured by using the 8-masks FBK-irst RF MEMS process. The performance was tested on 10 samples showing good mechanical reproducibility and negligible capacitance ratios variation (Cr=5.2±5%, Cr⁎=2.6±4%). Self-biasing tests have been performed by applying an equivalent Vrms on the RF central conductor, showing an insignificant capacitance ratio variation up to 13.5Vrms. Finally, cycling test was performed on the DUT up to 108cycles, showing negligible variation of the capacitance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.