Abstract
BackgroundNon‐contact Tonopachy NT‐530P (Nidek Co., LTD) provides intraocular pressure (IOP) and central corneal thickness (CCT) measurements. This study assesses the reliability and repeatability of its IOP measurements in young healthy adult subjects.MethodsIOP was determined in the right eye of 64 healthy patients using Tonopachy followed by the Canon TX-10 non-contact and Goldmann applanation (GAT) tonometers. Tonopachy IOP measurements were corrected (Tonopachy‐C) or not (Tonopachy‐NC) by the instrument for central corneal thickness. Central corneal thickness measurements provided by Tonopachy were also used to correlate (Pearson s coefficient) central corneal thickness with the GAT and Canon TX‐10 IOPs. Repeatability of Tonopachy and GAT was assessed in the right eye of 31 subjects in two separate sessions one week apart. Differences between pairs of instruments and between sessions were determined using Bland–Altman plots. The coefficient of repeatability was calculated as the 95% limits of agreement (LoA) of differences between the two sessions.ResultsTonopachy‐NC, Tonopachy‐C, Canon TX‐10 and the Goldmann tonometers showed a mean IOP of 14.62, 15.64, 15.02 and 14.68-mmHg, respectively. Tonopachy‐NC and Canon TX‐10 readings did not differ significantly from the Goldmann (p > 0.05), with close agreement with both tonometers (GAT versus Tonopachy‐NC: ‐3.84 to 3.96-mmHg; Goldmann versus Canon TX‐10: ‐4.75 to 4.07-mmHg). Tonopachy‐C readings differed significantly from Goldmann (mean difference ‐0.96-mmHg, p = 0.001, LoA from ‐5.09 to 3.17). Coefficients of repeatability were ± 3.70, ± 3.14 and ± 3.33-mmHg for GAT, Tonopachy‐NC and Tonopachy‐C, respectively. Central corneal thickness measured with Tonopachy was 530.42 ± 34.96 μm. There was a significant correlation between central corneal thickness and IOP for all tonometers except Tonopachy‐.ConclusionsReasonable agreement was observed between the Goldmann and Tonopachy. This instrument provides reliable and repeatable IOP measurements not influenced by central corneal thickness. The Tonopachy‐NC and Canon TX‐10 offer similar reliability compared to the Goldmann applanation tonometer in a young normotensive population.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.