Abstract

Semi-recumbent eccentric (ECC) cycling is increasingly used in studies of exercise with healthy and clinical populations. However, workloads are generally prescribed using measures obtained during regular concentric cycling. Therefore, the purpose of the study was to quantify the reliability of measures derived from a protocol that elicited peak ECC torque produced by the lower limb in a semi-recumbent position. Experiments were carried out on a dynamometer in a seated, semi-recumbent position identical to that of a custom-built ECC cycle, a modified Monark recumbent cycle. Thirty healthy participants completed two testing sessions. Each session comprised three series of six repetitions of a peak ECC torque protocol (PETP) on an isokinetic dynamometer. Absolute and relative reliability of peak torque, power, angle of peak torque, and work (recorded for each repetition) was determined using coefficient of variation (CV) and intraclass correlation coefficient (ICC), respectively. Ratings of perceived exertion (RPE), muscle soreness, and perceived effort (PE) were recorded pre-PETP, immediately post-PETP, and 1-min post each PETP. The protocol showed absolute reliability values <15% for mean peak (CV = 10.6–12.1) torque, power (CV = 10.4–12.3), angle of peak torque (CV = 1.2–1.4), and work (CV = 9.7–12.1). Moderate to high between-test relative reliability is reported for mean and highest torque (ICC = 0.84–0.95; ICC = 0.88–0.98), power (ICC = 0.84–0.94; ICC = 0.89–0.98), and work (ICC = 0.84–0.93; ICC = 0.88–0.98), respectively. Within-session peak torque, peak power, and peak work showed high relative reliability for mean (ICC = 0.92–0.95) and highest (ICC = 0.92–0.97) values. Overall, the PETP test provides a reliable way of determining peak ECC torque specific to semi-recumbent ECC cycling that may be used to prescribe workloads for this form of exercise.

Highlights

  • Eccentric (ECC) cycling is becoming increasingly common as a form of exercise in healthy and clinical populations and is the subject of an ever-growing number of fundamental and clinical research studies (Franchi and Maffiuletti, 2019)

  • Mean and individual max torque, power, angle of max torque, and work data recorded during each peak ECC torque protocol (PETP) for all participants are shown in Figures 2A–D, respectively

  • Our findings suggest that acceptable absolute and relative reliability can be achieved within one session with as little as six repetitions or less

Read more

Summary

Introduction

Eccentric (ECC) cycling is becoming increasingly common as a form of exercise in healthy and clinical populations and is the subject of an ever-growing number of fundamental and clinical research studies (Franchi and Maffiuletti, 2019). Workloads (intensity) for ECC cycling are commonly prescribed using measures obtained during CON cycling exercise (Franchi and Maffiuletti, 2019). These include maximal aerobic power output (Dufour et al, 2007), ventilatory threshold (Perrey et al, 2001), subjective ratings of perceived exertion (Laroche et al, 2013), or maximal aerobic heart rate (Rakobowchuk et al, 2018), as well as percentages of age-predicted maximal heart rates (Elmer et al, 2012)

Objectives
Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.