Abstract

The purpose of this study is to evaluate the test–retest reliability and construct validity of pinch and thumb strength measurements in subjects with de Quervain's disease. Maximal palmar pinch and thumb strength (adduction, extension, abduction, and flexion) were measured using, respectively, a pinch gauge and a biaxial dynamometer. The reliability was estimated using the generalizability theory. The validity hypotheses were as follows: 1) the pinch and thumb strength of the symptomatic side would be significantly lower than that of the asymptomatic side, and 2) the strength loss would be greater for thumb extension and abduction. The reliability was high for all strength measurements, pinch strength being the more reliable one. The pinch and thumb strength in all directions evaluated was significantly decreased on the symptomatic side (p < 0.003); no direction showed a greater decrease than the others. The results suggest that pinch and thumb strength measurements are reliable and able to show a decreased strength on the symptomatic side in this population.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.