Abstract

Abstract This paper presents a relay feedback technique for identification of dynamical systems for control purposes. The proposed technique uses a biased relay test with an added integration to determine three frequency response points for a phase lag in the range from 0 to 180° from a single experiment. This approach is based on a recently published method called “shifting method”. The additional integrator helps to improve the position of the frequency points obtained by the shifting method. The three frequency response points can be used for fitting up to five parameters of a process transfer function with various structures. The paper provides explicit formulas for determining the parameters of the second order model with a time delay from the obtained frequency response points. This approach can be used for the purpose of the controller design. The method is demonstrated on lag dominated, balanced and delay dominated processes. Matlab/Simulink programming environment was used for all experiments.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.