Abstract

In this study, it was evident that poly(vinylidene fluoride) (PVDF) membrane with a smooth surface (B2) displayed normalized flux as well as permeate flux superior to PVDF membrane with a rough surface (B1) during microfiltration. Before carrying out permeate flux and normalized flux tests, two PVDF membranes were prepared in order to obtain similar characteristics such as material, average pore size, and water contact angle value for the purpose of accurate comparisons under similar membrane preparation conditions. In flux performance tests where humic acid (HA) was used as feed solution, the permeate flux of the B2 membrane with the smooth surface was 12.02% higher (15.65L/m2h difference at 0.2bar) than that of the B1 membrane with the rough surface after 120min. Moreover, the B2 membrane also displayed higher normalized flux compared with the B1 membrane, which was caused by difference in surface structure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.