Abstract

A relationship between common-mode rejection and differential-mode distortion of the fully differential ladder Gm-C filters employing pseudo-differential transconductors is investigated. The equation which relates differential-mode HD3 and common-mode gain of the N th-order ladder Gm-C filters is derived. It has been found that in the cases where the inverter-based pseudo-differential transconductors are employed, the HD3 level of the odd-order filter is always lower than that of the even-order filter. By using the derived equation with the extracted parameters of certain inverter-based transconductors, it was found that by varying the common-mode gain from 0 to 1, the HD3 of the odd-order filters and even-order filters are decreased by 4.9 dB and increased by 3.1 dB, respectively. Simulation results are found to be in good agreement with the derived equation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.