Abstract

The authors discuss the relation of eddy current losses to dynamic domain behavior for very thin 3%Si-Fe strip-wound cores up to 5 kHz. The dynamic domain behavior was observed by using scanning electron microscope. The stripe domain structure B/sub 8/, and H/sub c/ were recovered after the strip was wound into a core and annealed above 800 degrees C. The wall bowing was negligible up to 1 kHz if the strip thickness was below 59 mu m. On the basis of these experiments, the measured domain wall numbers were compared with the calculated ones from Vm/He. The eddy current losses were calculated by applying the observed domain wall numbers to the modified Pry and Bean model and compared with the measured ones. The measured eddy current losses agreed comparatively well with the calculated ones above 500 Hz. The same tendency was obtained in the comparison of the observed domain wall numbers with the calculated ones. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.