Abstract

Heat transfer process and refrigerating characteristics of ice melting enclosed in a cube capsule are investigated using experiments and mathematical relations to achieve temperature control by ice storage in coal mine refuge chamber. The effective refrigerating time for ice storage capsule is defined and tested. The mathematical relations of the effective refrigerating time and refrigeration rate are derived and modified. The correction factor equation of ambient temperature and humidity is established for the revision of mathematical relations. By using the modification factor equation, the mean relative error between modified and experimental values is less than 1%. The three application parameters, namely tmodified, Ncapsule, and Nt,capsule are obtained based on the experiments and the modified relations. These parameters form the temperature control strategies in using ice storage capsule for refuge chamber. A 24-h manned experiment verifies the accuracy of the temperature control strategies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.