Abstract

We have studied the ability of reflective blankets to reduce net loss of body heat during regional anaesthesia for total hip arthroplasty. Thirty patients were allocated randomly to either the study group (insulated with reflective blankets) or the control group (no reflective blankets). Surgical and operation room draping, theatre temperature and i.v. fluid administration were standardized for all patients. Total body heat was deduced from core temperature (aural canal) and mean skin temperature (four measuring sites). After 2 h of surgery, loss of body heat was reduced significantly in patients wrapped in reflective blankets (26 kJ) compared with those in the control group (95 kJ).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.