Abstract
Alternating current (AC) electrical drives mainly require smaller current (or torque) ripples and lower total harmonic distortion (THD) of voltage for excellent drive performances. Normally, in practice, to achieve these requirements, the inverter needs to be operated at high switching frequency. By operating at high switching frequency, the size of filter can be reduced. However, the inverter which oftenly employs insulated gate bipolar transistor (IGBT) for high power applications cannot be operated at high switching frequency. This is because, the IGBT switching frequency cannot be operated above 50 kHz due to its thermal restrictions. This paper proposes an alternate switching strategy to enable the use of IGBT for operating the inverter at high switching frequency to improve THD performances. In this strategy, each IGBT in a group of switches in the modified inverter circuit will operate the switching frequency at one-fourth of the inverter switching frequency. The alternate switching is implemented using simple analog and digital integrated circuits.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Power Electronics and Drive Systems (IJPEDS)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.