Abstract
ObjectiveTo investigate the image quality (IQ) and apparent diffusion coefficient (ADC) of reduced field-of-view (FOV) di-ffusion-weighted imaging (DWI) of pancreas in comparison with full FOV DWI.Materials and MethodsIn this retrospective study, 2 readers independently performed qualitative analysis of full FOV DWI (FOV, 38 × 38 cm; b-value, 0 and 500 s/mm2) and reduced FOV DWI (FOV, 28 × 8.5 cm; b-value, 0 and 400 s/mm2). Both procedures were conducted with a two-dimensional spatially selective radiofrequency excitation pulse, in 102 patients with benign or malignant pancreatic diseases (mean size, 27.5 ± 14.4 mm). The study parameters included 1) anatomic structure visualization, 2) lesion conspicuity, 3) artifacts, 4) IQ score, and 5) subjective clinical utility for confirming or excluding initially considered differential diagnosis on conventional imaging. Another reader performed quantitative ADC measurements of focal pancreatic lesions and parenchyma. Wilcoxon signed-rank test was used to compare qualitative scores and ADCs between DWI sequences. Mann Whitney U-test was used to compare ADCs between the lesions and parenchyma.ResultsOn qualitative analysis, reduced FOV DWI showed better anatomic structure visualization (2.76 ± 0.79 at b = 0 s/mm2 and 2.81 ± 0.64 at b = 400 s/mm2), lesion conspicuity (3.11 ± 0.99 at b = 0 s/mm2 and 3.15 ± 0.79 at b = 400 s/mm2), IQ score (8.51 ± 2.05 at b = 0 s/mm2 and 8.79 ± 1.60 at b = 400 s/mm2), and higher clinical utility (3.41 ± 0.64), as compared to full FOV DWI (anatomic structure, 2.18 ± 0.59 at b = 0 s/mm2 and 2.56 ± 0.47 at b = 500 s/mm2; lesion conspicuity, 2.55 ± 1.07 at b = 0 s/mm2 and 2.89 ± 0.86 at b = 500 s/mm2; IQ score, 7.13 ± 1.83 at b = 0 s/mm2 and 8.17 ± 1.31 at b = 500 s/mm2; clinical utility, 3.14 ± 0.70) (p < 0.05). Artifacts were significantly improved on reduced FOV DWI (2.65 ± 0.68) at b = 0 s/mm2 (full FOV DWI, 2.41 ± 0.63) (p < 0.001). On quantitative analysis, there were no significant differences between the 2 DWI sequences in ADCs of various pancreatic lesions and parenchyma (p > 0.05). ADCs of adenocarcinomas (1.061 × 10-3 mm2/s ± 0.133 at reduced FOV and 1.079 × 10-3 mm2/s ± 0.135 at full FOV) and neuroendocrine tumors (0.983 × 10-3 mm2/s ± 0.152 at reduced FOV and 1.004 × 10-3 mm2/s ± 0.153 at full FOV) were significantly lower than those of parenchyma (1.191 × 10-3 mm2/s ± 0.125 at reduced FOV and 1.218 × 10-3 mm2/s ± 0.103 at full FOV) (p < 0.05).ConclusionReduced FOV DWI of the pancreas provides better overall IQ including better anatomic detail, lesion conspicuity and subjective clinical utility.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.