Three readback signal detection methods are presented for real-time head disk spacing variation measurement under vibration conditions. The proposed PW/sub 50/ parameter estimation method is not restricted by the isolated readback pulse signal requirement and, thus, can be used for spacing variation measurement in normally operated hard disk drives, especially for low-frequency variations. The thermal signal detection method, on the other side, is more effective for high-frequency spacing variation measurement. Amplitude detection gives a rough but simple way to study the head disk spacing change. Theoretical analysis and experimental results are given to illustrate the effectiveness of the methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.