Abstract

In this study, phase shifting method is used to modify moiré system into micro moiré interferometer which can measure displacement field with highly improved sensitivity. Apart from existing micro moiré technique, a low cost and less precise translation stage with rough resolution (10 μm resolution) is adapted for the phase shifter. Least square algorithm is applied to estimate the arbitrary phase shifted amount and to minimize the errors induced by lowering the cost. Moreover, specimen grating is phase shifted instead of reference grating which enables simple construction from given moiré system. To compensate for rigid body in-plane translation of specimen that may occur during phase shifting, pattern matching algorithm is put into practice to ensure pixel correspondence for each phase shifted images. To verify the newly constructed micro moiré technique, local displacement fields of Fine pitch Ball Grid Array package and Wafer Level Chip Size Package with elevated sensitivity up to 26 nm per fringe was acquired.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.