Abstract

PurposeRay propagation visualization and optical performance analysis of four different intraocular lenses (IOLs)MethodsIn this laboratory study, four IOLs with different optical designs were assessed: a monofocal AcrySof IQ SN60WF [Alcon], a diffractive-refractive bifocal AcrySof IQ Restor SN6AD1 [Alcon], a diffractive trifocal AcrySof IQ PanOptix TFNT00 [Alcon], and a diffractive extended-depth-of-focus (EDOF) Symfony ZXR00 [Johnson&Johnson]. An experimental set-up with a water bath containing 0.01% fluorescein solution and monochromatic green laser light (532 nm) was used to visualize the propagation of light rays. Also, the optical performance of the IOLs was evaluated by measuring the modulation transfer function (MTF) values at a pupil sizes of 3.0 and 4.5 mm on the optical bench OptiSpheric® IOL PRO II (Trioptics GmbH, Germany).ResultsBoth the diffractive-refractive bifocal IOL and the EDOF IOL showed two defined foci for distance and near vision. In the diffractive trifocal IOL, three distinct foci for distance, intermediate, and near vision could be visualized.ConclusionsThe ray propagation visualization technique allows a qualitative assessment and comparison of light energy distribution between different IOL models. The measured Through-Focus Response (TFR) quantitatively confirmed the evaluated ray propagation behavior.

Highlights

  • In recent years, various novel intraocular lens (IOL) models have been developed for the treatment of cataract and presbyopic patients

  • While monofocal IOLs still constitute the majority of the lenses implanted worldwide [1], multifocal IOLs (MIOLs) are swiftly gaining momentum, largely thanks to their ability to reduce spectacle dependence by generating functional vision in far, and in intermediate and near distances [2]

  • MIOLs that are refined with lathing techniques can minimize the intrinsic drawbacks of MIOLs by enhancing contrast sensitivity and reducing the perception of photic phenomena [4]

Read more

Summary

Methods

Four IOLs with different optical designs were assessed: a monofocal AcrySof IQ SN60WF [Alcon], a diffractive-refractive bifocal AcrySof IQ Restor SN6AD1 [Alcon], a diffractive trifocal AcrySof IQ PanOptix TFNT00 [Alcon], and a diffractive extended-depth-of-focus (EDOF) Symfony ZXR00 [Johnson&Johnson]. An experimental set-up with a water bath containing 0.01% fluorescein solution and monochromatic green laser light (532 nm) was used to visualize the propagation of light rays. The optical performance of the IOLs was evaluated by measuring the modulation transfer function (MTF) values at a pupil sizes of 3.0 and 4.5 mm on the optical bench OptiSpheric® IOL PRO II (Trioptics GmbH, Germany)

Introduction
Materials and methods
Discussion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.