Abstract

Controversy exists over the optimal dose of intravenous (i.v.) recombinant tissue plasminogen activator (rt-PA) and degree of blood pressure (BP) control in acute ischaemic stroke (AIS). Asian studies suggest low-dose (0·6 mg/kg) is more efficacious than standard-dose (0·9 mg/kg) i.v. rt-PA, and guidelines recommend reducing systolic BP to <185 mmHg before and <180 mmHg after use of i.v. rt-PA, despite observational studies indicating better outcomes at much lower (<140 mmHg) systolic BP levels in this patient group. The study aims to assess in thrombolysis-eligible AIS patients whether: (i) low-dose (0·6 mg/kg body weight; maximum 60 mg) i.v. rt-PA has non-inferior efficacy and lower risk of symptomatic intracerebral haemorrhage (sICH) compared to standard-dose (0·9 mg/kg body weight; maximum 90 mg) i.v. rt-PA; and (ii) early intensive BP lowering (systolic target 130-140 mmHg) has superior efficacy and lower risk of any ICH compared to guideline-recommended BP control (systolic target < 180 mmHg). The ENhanced Control of Hypertension And Thrombolysis strokE stuDy (ENCHANTED) trial is an independent,2 × 2 quasi-factorial, active-comparison, prospective, randomized, open blinded endpoint (PROBE), clinical trial that is evaluating Arm [A] 'rt-PA dose' and/or Arm [B] 'BP control', using central Internet randomization and data collection in patients fulfilling local criteria for thrombolysis and clinician uncertainty over the study treatments. The treatment arms will be analyzed separately. The primary study outcome in both trial Arms is death or disability according to the modified Rankin scale (mRS, scores 2-6) assessed at 90 days. Secondary outcomes include sICH, any ICH, a shift ('improvement') in function across mRS scores, separately on death and disability, early neurological deterioration, recurrent major vascular events, health-related quality of life, length of hospital stay, need for permanent residential care, and health care costs. Following launch of the trial in February 2012, the study has recruited more than 2500 patients across a global network of approximately 100 sites in 15 countries. The required sample sizes are 3300 for Arm [A] and 2300 for Arm [B], which will provide >90% power to detect non-inferiority of low-dose i.v. rt-PA and superiority of intensive BP lowering on the primary clinical outcome, respectively. Low-dose i.v. rt-PA and early intensive BP lowering could provide more affordable and safer use of thrombolysis treatment for patients with AIS worldwide.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.