Abstract

Massive gas injection rapid shutdown experiments have been conducted on the Alcator C-Mod tokamak using two toroidally separated gas injectors, in order to investigate the effect of multiple gas injection locations on the toroidal asymmetry in the radiated power. Toroidal radiation asymmetry is diagnosed by an array of six single-channel photodiodes mounted on the vessel wall. The presence of magnetohydrodynamic (MHD) activity is diagnosed using an array of magnetic pickup (Mirnov) coils, mounted on stalks on the vessel wall. Scans were conducted of the relative timing between the two jets, of the 95th percentile safety factor, and of the plasma elongation. It is observed that firing the two gas jets so that the injected impurities arrive at the plasma at nearly the same time produced an increase in the toroidal radiation asymmetry. In addition, the radiation asymmetry in the thermal quench phase correlates with the growth rate of low toroidal mode number MHD modes, indicating that these mode(s) are playing a role in setting the radiation asymmetry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.