In this study, we investigated four clinical cases of microbial contamination of in-use intravenous infusion fluid, detected by measuring "Adenosine triphosphate (ATP) + adenosine monophosphate (AMP)" ("ATP+AMP") levels. High "ATP+AMP" values correlate with microbial contamination, and by utilizing these values as indicator for microbial contamination possibility, we were able to rapidly detect the contamination and recommend replacement of catheters and administration sets. In three out of four cases, changing the infusion fluid led to improvement in the condition of the patients. "ATP+AMP" levels can be used to confirm microbial contamination of in-use intravenous infusion fluids, as it is fast (several minites) and convenient to measure them.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.