Abstract
In this research, a glassy carbon electrode (GCE) modified by MWCNT/chitosan NCs/Fe2O3 was prepared for the determination of the cephalosporin antibiotic cefditoren (CFT) using adsorptive stripping differential pulse and cyclic voltammetry techniques. The effects of pH, the scan rate, the deposition potential, the accumulation time, and modification agents on the determination of CFT were analyzed. The results showed that the modified electrode significantly increased the oxidation peak current of CFT. Under optimized conditions, the MWCNT/chitosan NCs/Fe2O3/GCE nanosensor exhibited a linear response between 0.2 µM and 10 µM toward CFT. The limit of detection and quantification were determined to be 1.65 nM and 5.50 nM, respectively. Model drugs (cefdinir, cefpodoxime, cephalexin, and ceftazidime compounds) were used to enlighten the CFT oxidation mechanism. Moreover, the nanosensor was used to analyze CFT in a pharmaceutical dosage form and commercial deproteinated human serum samples. The accuracy of these methods was proven in the recovery studies, with values of 96.98 and 98.62% for the pharmaceutical dosage form and commercial deproteinated human serum sample, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.