Abstract

Radon gas originating from building materials is generally thought to cause low concentration. Investigation and estimation of radon levels originating from building materials are important in terms of public health due to the use of dense concrete in tunnel form type houses, which is a building type widely used in Turkey, even though a significant part of Turkey is an earthquake zone. In this article, the effects of different parameters such as 238U concentration in building materials, diffusion constant of building elements, emanation rate, and ventilation rate on radon gas concentration are investigated. As a result, it is concluded that in some cases (such as high diffusion coefficient and insufficient ventilation rate) in houses built with tunnel form concrete structures, the radon level arising from building materials can reach a level that cannot be neglected.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.