Abstract

IntroductionAcute and late toxicity was analysed for prostate cancer patients with bilateral hip prostheses, who received fixed field intensity modulated radiotherapy (IMRT). The aims were (1) to establish whether toxicity rates differed from those of a control group with normal hips, (2) to develop a volumetric modulated arc therapy (VMAT) approach for patients with prostheses and (3) to compare doses to bladder and rectum for the control group, prostheses group and VMAT replans for the prostheses group.MethodsGenitourinary (GU) and gastrointestinal (GI) toxicity was scored using Common Terminology Criteria for Adverse Events version 5.0. The incidence of grade 2 or worse (G2+) toxicity was compared using Fisher’s exact test. Dose volume histograms (DVHs) and mean doses to organs at risk (OARs) were compared using signed rank tests.ResultsThere were 17 patients in the prostheses group and 50 in the control group. Acute and late GU toxicity was similar. G2+ late GI toxicity incidence was 31% for the prostheses group and 14% for the control group (p = 0.14). Significant differences (p < 0.05) were seen between the OAR DVHs of the prostheses group who had IMRT and the control group for a range of intermediate doses. The rectum mean dose was significantly different (p < 0.001), but no difference was seen for the bladder mean dose (p = 0.08).ConclusionsNo significant differences were seen in GU and GI toxicity incidence between patients with bilateral hip prostheses and a control group. The DVHs for bladder and rectum were significantly higher for patients with prostheses planned with IMRT. Replanning using a VMAT technique significantly reduced doses to the OARs, whilst maintaining good planning target volume coverage.

Highlights

  • Acute and late toxicity was analysed for prostate cancer patients with bilateral hip prostheses, who received fixed field intensity modulated radiotherapy (IMRT)

  • Treating patients with hip prostheses is challenging [4] due to artefacts in computed tomography (CT) images making it hard to accurately delineate the clinical target volumes (CTVs) and organs at risk (OARs) [5], difficulties in determining

  • The primary goal of this study was to determine whether the incidence of GU and GI toxicities following radiotherapy for prostate cancer differed between a group of patients with bilateral hip prostheses and a control group

Read more

Summary

Introduction

Acute and late toxicity was analysed for prostate cancer patients with bilateral hip prostheses, who received fixed field intensity modulated radiotherapy (IMRT). The aims were (1) to establish whether toxicity rates differed from those of a control group with normal hips, (2) to develop a volumetric modulated arc therapy (VMAT) approach for patients with prostheses and (3) to compare doses to bladder and rectum for the control group, prostheses group and VMAT replans for the prostheses group. Doses to the rectum and bladder were analysed and a comparison made between fixed field intensity modulated radiotherapy (IMRT) as used for treatment and volumetric modulated arc therapy (VMAT) plans for the group with prostheses

Objectives
Methods
Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.