Abstract

An investigation into the nature of transients occurring when keying takes place shows that objectionable features of these transients may be reduced by suitable precautions. In the usual form of low-pass plate-supply filter, high C or low L are essential preventives of transients, and poor voltage regulation sometimes reduces their harmful effects. The transient is a damped sinusoid causing an initial drop in plate voltage when the key is closed. Two-section filters produce a double-frequency transient, the low-frequency component being the more important. Theoretical deductions are confirmed by oscillographic measurements on both rectifier and generator plate supplies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.