To study the angle of screw placement in relation to the scaphoid fracture plane and its effect on union after percutaneous fixation of scaphoid waist fractures. Twenty-four consecutive scaphoid waist fractures were retrospectively evaluated for the orientation of screws in relation to the fracture plane using a method in which the sum-of-smaller angles (SSA) in 3 different radiographs were used to correlate with time to fracture union. All but one patient achieved union after percutaneous fixation of the scaphoid. Another patient required revision surgery within the study period for inadequate fixation. A shortened time to union was significantly correlated to larger SSA. SSA may be a reasonable predictor of union after percutaneous fixation of scaphoid waist fracture. It can be reliably calculated using plain radiographs. An SSA of 190° or more correlated with union by 8 weeks postoperatively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.