Abstract
The possibility of increasing the sensitivity of radiation sensors based on the field effect transistors is experimentally studied. A bridge circuit connecting two transistors with positive sign of the radiation sensitivity and two transistors with negative sign of the radiation sensitivity makes it possible to increase the dependence of the output voltage in the bridge diagonal on the absorbed radiation dose by an order of magnitude. The frequency sensor-converter of radiation designed on a unijunction transistor according to the circuit of the relaxation oscillator has the minimum number of individually attached components. The replacement of the resistor setting the current in the emitter circuit with a field-effect transistor sensitive to radiation increases the sensor sensitivity 5–10 times.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Communications Technology and Electronics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.