Abstract

This prospective study investigated radiation exposure dose (RED) to main operator (MO) and supervisory operator (SO) performing dypiridamole stress testing in a 1-d rest/stress 99mTc tetrofosmin single-photon emission computed tomography (SPECT) of consecutive 42 patients. MO was instructed to be close to the patients during the entire procedures including the vasodilator and radiotracer injection. SO mainly recorded the data on the procedures apart from the patients. RED, procedure time (PT) and internal radioactivity (IR) of patients were measured before and after a secondary tracer injection for stress SPECT, respectively. RED was significantly greater to MO than to SO (6.2 ± 2.7 vs 2.5 ± 2.1 μSV per stress procedure, p < 0.0001). Multivariate analyses revealed that IR and PT were significantly independent factors to predict RED to both operators. Operators performing pharmacologic stress procedure should be aware that IR and PT are independent factors for RED in 99mTc myocardial perfusion imaging.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.