Abstract
We designed and fabricated AC-coupled silicon strip sensors that could be good detectors for X-ray imaging, particle detection, radiation monitoring, etc. Silicon sensors are known to have good position and energy resolution, but to be susceptible to radiation damage. Therefore, it is important to test the effects of radiation damage to the fabricated AC-coupled silicon strip sensors. For this purpose, the 45 MeV proton beam from the MC-50 cyclotron at the Korea Institute of Radiological and Medical Science (KIRAMS) in Seoul, Korea, was used. Four AC-coupled silicon strip sensors were exposed to 10 ∼ 10 proton fluences, and the total leakage current was measured and analyzed by comparing the results before and after the proton beam irradiation, and essential progress in the understanding of radiation-induced detector deterioration is presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.