Abstract

We report on radial dose distributions for carbon ions calculated with Geant4-DNA code. These distributions characterize ion tracks on a nanoscale and are important for understanding the biological effects of ion beams. We present data for carbon ion beams in the energy range from 20 to 400 MeV u−1. To approximate the Monte Carlo results, we developed a simple formula that combines the well-known inverse square distance dependence with a factor correcting for small . The proposed formula can be used to calculate for any energy within the above range and for distances from 1 nm to 2 μm with a maximum error not exceeding 14%. This range of distances corresponds to a dose range of over seven orders of magnitude. Differences between our results and those of previously published analytical models are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.