Abstract
Currently available HVAC units for trains are commonly using either HFC-134a (75%) or HFC-407C (25%) as working fluids, which have a significant global warming potential when released into the environment. These units typically rely on inefficient direct electrical heating to cover heating demands. However, some system suppliers can offer HFC-134a HVAC systems with heat pump capabilities able to supply heating to the coach at ambient temperatures above -5 °C. Deutsche Bahn has analysed the energy consumption of their Railway Rolling Stock in detail over several years. Up to 30 % of their total energy consumption has to be spent to operate the HVAC units of the passenger trains in Germany. Only the propulsion system requires a larger share of the total energy. In Norway the energy consumption for heating up the train compartments is dominating, due to the high amount of operating hours at low ambient temperatures. The paper describes the development status of an energy efficient and environmentally friendly HVAC unit applying R744 for trains. The pilot unit will be tested on a Norwegian train operated in the Oslo area from summer 2016.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.