Abstract
This letter describes quantitative nondestructive measurements of multilayer submicron Cu/SiO2 interconnect structures such as Cu lines, vias, and W lines with lateral dimensions down to 300 nm and electromigration defect structures using scanning transmission x-ray microscopy employing a 0.2 μm x-ray beam. Typical measurement accuracies are ⩽60 nm for widths and lengths and ⩽10% in height. The high-resolution and nondestructive nature of this technique provide a very powerful probe of physical properties of nanoscale and submicron materials and structures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.