Abstract

AbstractA specific and sensitive method for the determination of ethylenediamine in human plasma is described. The aqueous sample is treated with m‐toluoyl chloride, yielding the N,N′‐bis(m‐toluoyl) derivative of the diamine, which is extracted into dichloromethane and quantitated after “on column” methylation by capillary gas liquid chromatography with alkali flame ionization detection. The corresponding derivative of putrescine serves as internal standard. The assay is reproducible and calibration curves are linear over the concentration range 0.05 to 10 μg · ml−1. The lower detection limit is about 10 ng · ml−1. The structures of the compounds of interest eluting from the capillary column are examined by gas liquid chromatography/mass spectrometry. The assay has been applied to the analysis of ethylenediamine in plasma following the administration of aminophylline and ethylenediamine in a cross‐over study to patients with bronchopulmonary diseases. The method also proves suitable for measuring other primary and secondary amines and diamines in aqueous solutions by gas liquid chromatography.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.