A highly sensitive and specific quantitative assay for the determination of albuterol in human plasma, based on selected ion monitoring gas chromatography chemical ionization mass spectrometry, has been developed. The [MH]+ ions from the tri-TMS derivatives of albuterol (m/z 456) and the internal standard (2H3)albuterol (m/z 459), were assayed simultaneously by selected ion monitoring. The lower limit of quantitation is 0.25 ng ml-1 and the average assay precision (CV) for albuterol concentrations ranging from 0.25 ng ml-1 to 25 ng ml-1 is approximately 4%. This method is currently being employed for the routine quantitation of albuterol in plasma following the administration of doses therapeutically effective to man.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.