Abstract
Small amounts of contaminants may lead to false-positive results in sensitive polymerase chain reaction (PCR) detection systems. To analyze contaminants and understand the usability of beta-glucanases in fungal preparations, we estimated the ribosomal DNA (rDNA) contamination in Zymolyase-100T and Lyticase by quantitative PCR. The amount of rDNA contamination determined by real-time PCR was 9210 copies/unit for Zymolyase-100T and 0.0323 copies/unit for Lyticase. The observations regarding these enzyme products indicate that careful consideration of contaminating DNA included in the reagents used for molecular diagnostics is necessary.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.