Abstract
The behaviors of electrode displacement and force during spot welding under various conditions, such as different weld currents, electrode forces, and welding times, were studied. Tests were conducted on a 170 kVA MFDC spot welder. Data were collected via a multichannel high-speed data acquisition system and were analyzed with MATLAB. Behaviors of 5182 aluminum and mild steel in spot welding were compared. Results show that nugget expansion rate does not reach zero for aluminium as it does for mild steel as nugget grew to a certain size. A linear relationship is found between the nugget size and maximum expansion that facilitates online weld quality evaluation. An electrode force peak is observed and believed relevant to the sufficient nugget size.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.