Abstract

Informative parameters for statistical estimation of operational error of SAMGAS, METRIX, PREMAGAS household gas meters (HGM) are formulated. These are the values of the measured volume during the verification period of operation and the experimentally determined error of the meter during operation at three normalized flow rates: minimum, maximum and 20% of the maximum.
 Six ranges of variation of the HGM error at the minimum flow rate were selected to form statistical samples of meters. According to the proposed algorithm, the change in the weighted average HGM error for three normalized flow rates from the measured volume is quantified, taking into account the number of HGMs and their error ranges. It is proposed to apply the concept of generalized weighted average error of HGM, which reflects the operational error of HGMs during their operation in the entire range of consumption when measuring gas volumes up to 60 thousand cubic meters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.