Abstract

Seven patients with acquired ptosis and normal levator function following anterior radial keratotomy are presented. Five of these patients then elected to undergo radial keratotomy of the opposite eye, and four had symmetrical lid fissures (mild bilateral ptosis) after bilateral surgery. Ptosis is a wellknown complication of cataract extraction, but has not been reported following radial keratotomy. Unlike cataract extraction, radial keratotomy does not require anesthetic injections, bridle sutures, or conjunctival flaps. The rigid Knapp eyelid speculum used in these cases remains as the only apparent cause of eyelid trauma and subsequent ptosis. During radial keratotomy, the speculum was opened widely in order to provide good corneal exposure and avoid contact with the diamond knife. Contraction of the orbicularis oculi muscle against the rigid speculum may have traumatized the lid, resulting in a levator aponeurosis disinsertion and subsequent ptosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.