Abstract
The need of circulatory support systems in the treatment of chronic heart failure is increasing constantly, as 20% of the patients on the waiting list die every year. Despite the great need for mechanical heart support systems, the use of available systems is limited by its expensiveness. In addition, there is no one system that is 100% responsible to all medical and technical requirements and that would be completely safe for patient. Therefore, further research in the field of circulatory support systems considering health and technical requirements is relevant. One of the new directions in the study are disc pumps of viscous friction for liquid transporting, based on the Tesla pump principle. The operation principle of such pumps is based on the phenomenon of the boundary layer which is formed on the disk rotating in a fluid. There are experimental studies of models with different variants of the rotor suspension, various forms and numbers of the disks, forms of the pump housing. However, none of the above samples was brought to clinical trials. Furthermore, despite the potential of that model there have been no pumps of similar type used so far in circulatory support systems. Published data provide a basis for further development and testing of the pump model and allow hoping for leveling a number of significant shortcomings of modern left ventricular bypass systems.
Highlights
The need of circulatory support systems in the treatment of chronic heart failure is increasing constantly, as 20% of the patients on the waiting list die every year
Despite the great need for mechanical heart support systems, the use of available systems is limited by its expensiveness
There is no one system that is 100% responsible to all medical and technical requirements and that would be completely safe for patient
Summary
The need of circulatory support systems in the treatment of chronic heart failure is increasing constantly, as 20% of the patients on the waiting list die every year. E-mail: a_fomichev@list.ru research in the field of circulatory support systems considering health and technical requirements is relevant. Это защищает перекачиваемую плазму крови и форменные элементы крови от механического повреждения, которое образуется при прямом контакте элементов крови и ротора насоса. В работах G.E. Miller [5, 6] приводятся результаты исследования работы центробежного дискового насоса Тесла
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Russian Journal of Transplantology and Artificial Organs
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.