Abstract

This study investigated the effect of variation in proportioning polysulfide base and catalyst. Light, regular, and heavy-bodied pastes were mixed in linear equivalents of base-to-catalyst proportions of 30 70 , 40 60 , 50 50 , 60 40 , and 70 30 . Compression set, strain in compression, and consistency tests conformed to the American Dental Association (ADA) Specification 19 guidelines. The amount of solvent-leachable components and differences in the cross-linked nature of the cured products were studied. Compression set and strain in compression tests met the ADA specification guidelines. Some consistency values fell outside of the ADA specification limits. The leachable content increased with increasing proportions of catalyst, but polymer cross-linking was remarkably similar for all bodied materials tested. Clinicians need not fear a significant property alteration in polysulfide impression material by the differences (within ±20% of the manufacturer's suggested lengths) in proportioning the component pastes with “eyeball” estimation as directed in the instructions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.