Vertical comb drive actuator has been widely employed in MEMS scanning mirror, but more process challenges occur when it goes to high aspect ratio comb structures for high stroke application. This paper reports a novel process to fabricate self-aligned vertical comb drive actuator with aspect ratio up to 40. With this process platform, some process limitations can be lifted, while a vertical comb drive actuator with non-resonant scan angle larger than 20° can be obtained. A 2D scanning mirror with large scan angle is taken as an example to demonstrate this platform.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.