Abstract

BackgroundCatheter-associated urinary tract infections (CAUTIs) are the most common infections found in healthcare facilities. Urinary catheters predispose the development of CAUTIs by destroying natural barriers and providing a source for infection and biofilm formation (BF). This study aimed to evaluate probiotic lactic acid bacteria (LAB) as a means of preventing in vitro urinary catheter colonization and BF.MethodsCross-sectional screening, followed by an experimental study, was conducted on 120 catheterized patients admitted to the urology department in a tertiary care hospital for 7 months. The isolated and identified uropathogens were tested for their antimicrobial susceptibility patterns by the disk diffusion method according to Clinical and Laboratory Standards Institute recommendations and examined for their ability to produce biofilms using a microtiter plate (MtP) assay. Five LAB (Lactobacillus acidophilus (L. acidophilus), Bifidobacterium bifidum (B. bifidum), L. paracasei, L. pentosus, and L. plantarum) were identified and examined for preventing in vitro colonization and BF of some isolated uropathogens on Foley urinary catheter surfaces.ResultsOf the 120 samples collected, 32.5% were found to be associated with CAUTIs. Of isolated organisms, 74.4% were gram-negative bacilli, while gram-positive cocci represented 14%, and only 11.6% were of the Candida species. About two-thirds of isolated uropathogens were biofilm formers. All five probiotic strains had inhibitory effects on the growth of all the uropathogens tested but with varying intensities according to the duration of application after 2, 4, and 6 days.ConclusionsThe prevalence of CAUTIs was high, and the predominant bacterial isolates were gram-negative bacilli. Many of the studied uropathogens were biofilm formers. The bacterial isolates had a higher prevalence of resistance to commonly prescribed antimicrobial agents. Probiotics have the potential to prevent in vitro urinary catheter colonization and inhibit BF. Pre-coating urinary catheters with probiotics is recommended after ensuring the safety of probiotics’ use in vivo by carrying out further large-scale studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.