Abstract

<para xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> Preliminary comparisons between numerical simulation and experimental results are obtained under pulsed applied voltages in the case of positive point to plane corona discharges in dry air at atmospheric pressure. The experimental conditions correspond to 7 mm interelectrode distances with a tip radius of 20 <formula formulatype="inline"><tex>$\mu\hbox{m}$</tex></formula>. The calculations are based on a first-order 2-D electrohydrodynamic model including the main charged-particle/gas reactions occurring in dry air discharge. The development of the corona discharge is analyzed using streak camera pictures. The transition from the branching structure to the monofilamentary one is described. An interesting comparison is performed between the streak camera pictures and the spatiotemporal evolution of the calculated ionization rate. This shows a qualitative agreement in the development of both primary and secondary streamers. </para>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.